Search results for "Helical tomotherapy"

showing 3 items of 3 documents

Hypo-fractionated stereotactic radiation therapy for lung malignancies by means of helical tomotherapy: report of feasibility by a single-center expe…

2018

Background: Several experiences in the literature report SBRT as an effective treatment option for medically inoperable early stage non-small cell lung cancer (NSCLC) and oligometastatic disease. The optimal fractionation schedules and total dose remain controversial. In this study, we evaluated the safety in terms of toxicity and efficacy of using of 8–10 fractions schedules with Helical Tomotherapy (HT) for primary and metastatic lung lesions. Methods: Between March 2014 and May 2016, a total of 39 patients (median age 72 years, range 26–91) were treated with HT-SBRT for malignant lung lesions: 22 patients with early stage NSCLC, 17 with oligometastases. Patients received 8–10 fract…

AdultMalemedicine.medical_specialtyLung Neoplasmsmedicine.medical_treatmentStereotactic radiation therapyRadiosurgerySingle CenterTomotherapy030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineHelical tomotherapyCarcinoma Non-Small-Cell LungmedicineHumansRadiology Nuclear Medicine and imagingStage (cooking)Lung cancerAgedPneumonitisAged 80 and overSBRTHelical tomotherapy; Lung cancer; Radiotherapy; SBRTRadiotherapybusiness.industryRadiotherapy DosageGeneral MedicineMiddle Agedmedicine.diseaseSurvival RateRadiation therapyTreatment Outcome030220 oncology & carcinogenesisFeasibility StudiesFemaleDose Fractionation RadiationRadiologyLung cancerbusinessTomography Spiral ComputedEsophagitis
researchProduct

END-TO-END TEST IN STEREOTACTIC RADIOSURGERY TREATMENTS THROUGH HELICAL TOMOTHERAPY

2020

STEREOTACTIC RADIOSURGERY HELICAL TOMOTHERAPY
researchProduct

Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments

2016

Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. This tecnique allows to deliver high doses of radiation to the tumor sparing the surrounding healthy tissue. In this study the accuracy of the dose delivered in a SRS session by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test. This is perfome d by means of alanine Electron Paramagnetic Resonance (EPR) pe llets. The response of these dosimeters is compared to that of gafchromic films which are particularly suitable for two-dimensional dose verification providing accura…

Settore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaESR EPR Dosimetry Helical TomotherapyStereotactic Radiosurgery treatmentsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct